Description
Overall, the Taco SR506-2(4) offers a compact, expandable, and multi-functional control solution for managing multiple zones and a circulator pump in hydronic heating systems. Its priority function, diagnostic lights, compatibility with various valve types, built-in transformer, and circulator relay make it a versatile choice for efficient and customizable temperature control.
Function:
- Manages water flow to 6 zones in a hydronic heating system, ensuring efficient zone-based temperature control.
- Activates and deactivates a circulator pump to maintain continuous water circulation when needed, optimizing system performance.
- Offers a switchable priority function for one zone, allowing it to take precedence over others when activated.
Key Features:
- 6-zone capacity (expandable): Suitable for small to medium multi-zone systems, with the option to add more zones using expansion modules.
- Switchable priority: Prioritizes one zone over others when needed, ensuring immediate comfort or addressing critical areas.
- External diagnostic lights: Facilitate troubleshooting by indicating system status and zone operation.
- Compact design: Optimizes space utilization in control panels.
- Compatible with various valve types: Works with 2-, 3-, or 4-wire zone valves for flexibility in system design.
- Built-in circulator relay: Eliminates the need for a separate relay to control the circulator pump, simplifying wiring and installation.
- Field-replaceable transformer: Facilitates easy maintenance if needed.
- Universal thermostat compatibility: Works with a wide range of thermostats.
- Fuse-protected: Ensures electrical safety.
Applications:
- Hydronic heating systems (radiant, baseboard, fan coil)
- Closed cooling circuits (zoned air conditioning)
- Hydronic heating and cooling systems (combined heating and cooling zones)
Things to Consider:
- System compatibility: Verify compatibility with your system’s voltage, control signals, and valve types.
- Installation complexity: While DIY installation is possible, consulting a qualified professional is recommended for optimal performance and safety.
- Expansion modules: If you need more than 6 zones, additional SR506-2(4) units will be required.